公司研制的30串鋰電動(dòng)力電池保護(hù)板,本產(chǎn)品嚴(yán)格滿足ROHS規(guī)范等。This specification applies to the 30 serial-cells lithium manganese battery protection board, which strictly conforms to the ROHS standard.
二、應(yīng)用范圍Application
鋰離子、聚合物鋰電池等可充電鋰電池包。Applies to the rechargeable Lithium battery packs and so on.
三、電氣參數(shù)Electrical Characteristic (Ta = 25 ℃.)
Details詳細(xì)項(xiàng)目 Min. Typ. Max Error Unit
Battery Gas電池類型 3.2V鋰電池(鐵電)
Battery Link電池組組合方式 30S 分口
Loop capability回路性能
Input Charging Voltage 充電輸入電壓 114 ±1% V
Input Charging Current 充電輸入電流 5 *大7A A
Output Discharging Voltage放電電壓(平臺(tái)工作電壓) 96 V
Continuous Output Discharging Current(可持續(xù)工作電流) ≤60 A
Protection Parameters (for Individual Cell).保護(hù)參數(shù)(對(duì)于每節(jié)電芯)
Over-Charge Voltage Protection (OVP) 過充保護(hù)電壓 / 3.800 / ±25mV V
Over-Charge Protection Delay Time (OCPDT)過充保護(hù)延時(shí) / 1000 / ±200mS mS
Over-Charge Voltage Protection Release (OVPR)過充恢復(fù)電壓 / 3.650 / ±50mV V
Over-Discharge Voltage Protection (UVP)過放保護(hù)電壓 / 2.300 / ±80mV V
Over-Discharge Voltage Protection Release (UVPR)過放恢復(fù)電壓 / 2.30-2.50 / ±100mV V
Over-Discharg Protection Delay Time (ODPDT)過放保護(hù)延時(shí) / 100 / ±50mS mS
Over-Discharg Discharge Protection (OCDP)放電過流保護(hù) / 150 / ±20A A
Over-Current Protection Delay Time (OCPDT)過流保護(hù)延時(shí) / 100 / ±50mS mS
開負(fù)載
Discharging Temperature放電保護(hù)溫度(高溫) --- 75 --- ±5 ℃
Discharging Temperature Protection Release放電保護(hù)恢復(fù)溫度 --- 55 --- ±5 ℃
Discharging Temperature放電保護(hù)溫度(低溫) --- -20 --- ±5 ℃
Discharging Temperature Protection Release放電保護(hù)恢復(fù)溫度 --- -10 --- ±5 ℃
charging Temperature充電保護(hù)溫度(高溫) --- 55 --- ±5 ℃
charging Temperature Protection Release充電保護(hù)恢復(fù)溫度 斷開充電器(小于45℃) ±5 ℃
charging Temperature充電保護(hù)溫度(低溫)0±5 ℃
ch |
 |
|