Performance性能
1 Standard Test Condition標(biāo)準(zhǔn)測(cè)試條件
The tested battery must be a new battery with production time less than one month, the charge and discharge cycle less than 5 times. Unless there were other particular requirements, the testing condition for this specification is: temperature 15~35℃, relative humidity 45%~75%, atmospheric Pressure 86~106kPa.
測(cè)試電池必須是本公司出廠時(shí)間不超過一個(gè)月的新電池,且電池未進(jìn)行過五次以上充放電循環(huán)。除非其它特殊要求,本產(chǎn)品規(guī)格書中的測(cè)試條件為:溫度15~35℃,相對(duì)濕度45%~75%的條件,大氣壓力86~106kPa。
2 Measurement Apparatus Request測(cè)試設(shè)備要求
(1)The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.
測(cè)量尺寸的儀器精度應(yīng)大于等于0.01mm。
(2)萬用表測(cè)量電壓及電流的準(zhǔn)確度應(yīng)不低于0.5級(jí),測(cè)量電壓時(shí)內(nèi)阻不應(yīng)小于10kΩ/V。
The precision of multimeter should be not low than 0.5 class, inner impedance not less than 10 kΩ/V.
(3)內(nèi)阻測(cè)試儀測(cè)量原理應(yīng)為交流阻抗法(1kHz NLCR)。
Impedance shall be measured by a sinusoidal alternating current method(AC 1kHz LCR meter).
(4)電池測(cè)試系統(tǒng)的電流精度應(yīng)在±0.1%以上,恒壓精度±0.5%,計(jì)時(shí)精度不低于±0.1%。
Current test precision rate above 0.1%, CV precision rate ±0.5%, timing precision rate no less than ±0.1%.
(5)測(cè)量溫度的儀表準(zhǔn)確度應(yīng)不低于±0.5℃。
湖南合一能源科技有限公司,低溫鋰電池生產(chǎn)制造專家,更多產(chǎn)品信息詳見合一電池工廠網(wǎng)站。