適用范圍'
適用于夾持和固定各種類型的鋼絲鎧裝電纜 ;
隔爆要求,要求殼體密封達IP66的場所。
Applying scope
Suitable for clamping and fastening various kinds of steel wire armored cables;
Flame-proof requirement: It should be used on enclosure with IP66 degree of protection.
技術數據
防爆標志:ExdII、ExeII;
標準工作溫度范圍:-60℃~+100℃;
防護等級:IP66;
密封接頭的設計符合GB3836和BS6121。
Specification
Ex-marking: ExdII, ExeII;
Standard working temperature scope: -60℃ 100℃;
Degree of protection: IP66;
The design of cable gland is in accordance with GB3836 and BS6121."公制螺紋M
(S為標準品)" 電纜直徑密封范圍mm 螺紋長度GLmm 長度Hmm 對邊直徑mm
"除鎧電纜外徑
*大(出線Amm)" "電纜外徑
范圍(進線Bmm)"
M20S 10 9.0-16.0 15 50 24
M20 13 12.5-20.5 15 52 30
M25S 13 12.5-20.5 15 52 30
M25 18 17.0-26.0 15 58 37
M32S 18 17.0-26.0 19 58 37
M32 24 22.0-33.0 19 62 45
M40S 24 22.0-33.0 19 62 45
M40 29 28.0-41.0 19 69 55
M50S 29 28.0-41.0 19 69 55
M50 35 36.0-52.5 19 77 65
M63S 35 36.0-52.5 19 77 65
M63 50 46.0-65.0 19 95 82
M75S 55 46.0-65.0 19 95 93
M75 64 57.0-78.0 19 100 110
M90 75 68.0-88.0 19 100 121
M115 90 83.0-103.0 19 106 13 |
 |
|